(4.3) Monitoring Conditions:
(4.3.1)
Manufacturers shall define the monitoring conditions for malfunctions identified in sections (e)(4.2.2)(A) and (B) (i.e., purge flow and 0.040 inch leak detection) in accordance with sections (d)(3.1) and (d)(3.2) (i.e., minimum ratio requirements).
(4.3.2)
Manufacturers shall define the monitoring conditions for malfunctions identified in section (e)(4.2.2)© (i.e., 0.020 inch leak detection) in accordance with sections (d)(3.1) and (d)(3.2) (i.e., minimum ratio requirements). For purposes of tracking and reporting as required in section (d)(3.2.2), all monitors used to detect malfunctions identified in section (e)(4.2.2)© shall be tracked separately but reported as a single set of values as specified in section (d)(5.2.2).
(4.3.3)
Manufacturers may disable or abort an evaporative system monitor when the fuel tank level is over 85 percent of nominal tank capacity or during a refueling event.
(4.3.4)
Manufacturers may request Executive Officer approval to execute the evaporative system monitor only on driving cycles determined by the manufacturer to be cold starts if the condition is needed to ensure reliable monitoring. The Executive Officer may not approve criteria that exclude engine starts from being considered as cold starts solely on the basis that ambient temperature exceeds (i.e., indicates a higher temperature than) engine coolant temperature at engine start. The Executive Officer shall approve the request upon determining that data and/or an engineering evaluation submitted by the manufacturer demonstrate that a reliable check can only be made on driving cycles when the cold start criteria are satisfied.
(4.3.5)
Manufacturers may temporarily disable the evaporative purge system to perform an evaporative system leak check.